Condensate Control  is an easy to use, liquid treatment which neutralises the acids occurring in the condensate system. The highly effective product maintains an alkali condition from the condenser onwards, throughout the system.

 

Condensate Control  is a liquid, volatile alkaline amine which neutralises the acid contaminants of condensate and feed water systems, so preventing the acid corrosion of system components.  The most common cause of acid corrosion in condensate and feed water systems is carbonic acid, which is the result of dissolved carbon dioxide (CO2) being present in the water.  Condensate Control  neutralises these acids and maintains the condensate and feedwater in an alkaline condition.

 

 Condensate Control  volatilises and carries over with the steam and so is recycled.  Dosage is economical and efficient.When using Condensate Control as part of your normal maintenance care of your boiler or feed water system you will reduce the operating costs and increase the reliability of your system.Condensate Control  can be used in virtually any system requiring protection for acid conditions.

 

The condensate is tested for pH to determine the dosage level.  The minimum pH should be 8.3 the optimum would be between pH 8.5 and 9.0. A typical dosage for an average 10 metric tonne system would be 0.75L/day

 

DOSING METHOD

 

Condensate Control  is best dosed using a metering pump or a flow meter arrangement.  The treatment can be dosed together with oxygen control.

 

 

Suitable dosage points are

• Condensate pump discharge.

• Hot well or condensate drain tank (with the feed

        line at least 1 meter below the surface

 

Applications

 

CONDENSATE CONTROL is injected into the condensate pump discharge frequently to prevent corrosion in the steam and condensate lines. It can also be used to protect idle boilers from corrosion.

 

Directions for use

 

The regular dosage of CONDENSATE CONTROL depends largely on the amount of carbon dioxide that has dissolved into the condensate. CONDENSATE CONTROL should be injected into the condensate line frequently to maintain a pH between 8.3 – 9. A typical dosage for a 10 ton system would require 0.25 l per day. Increase or decrease the dosage with 25% if the daily dosage does not result in the required pH value.

 

CONDENSATE CONTROL may be added into the feedwater. However, it must be injected into the feed line and not into the cascade tank. This is to ensure that the product does not volatilize before entering the boiler.