Primary tabs

FREE SHIPPINGFree shipping on all orders over 100000 INR.

Vapor Treatment

0
No votes yet
SKU::RXSOL-51-6001-025

Product Qty Per Unit: 
25.00
Product usage unit: 
Ltr.

Negotiate Price

Product Delivery Locations: 
Haldia Port, Kolkata Port Trust, Dhamra Port, Paradip Port
Category: 
Evaporator Treat-51
Generic Name: 
Evaporator Treatment Chemicals
Neutral Liquid for prevention of scale in seawater Evaporators
Product Description: 

VapourTreatment  For controlling of Scale & Foam ::: Neutral Liquid for prevention of scale in seawater Evaporators
This is a highly Active Antifoulant, Water Scale Inhibitor, Dispersant and Anti-precipitant compound for use in industrial and Marine Water systems, such as cooking systems, Heat Exchangers, air conditioning equipment, etc.

 

Product Application: 

Procedure Of Use and Dose Rates: POLYELECTROLYTE  polymer  of RXSOL-51-6001-025 reacts with the potential scale forming salts in the water to prevent them from adhering to heat transfer surfaces. These solids are held in suspension and  easily removed  from  the evaporator  line. Finally RXSOL-51-6001-025 also have defoaming properties by which will stop foaming in EVAPORATOR. And by that way Distilled water quality is maintained in side the EVAPORATOR.

Used in both high and low pressure evaporators. 

Product Procedure: 

Dosage :

Daily Out Put Evaporator Daily  RXSOL VT 6001 Requirement
10 -20 MT 100-200 ML
30-40 MT 300-400 ML
50-60 MT 500-600



Setting the Flow Rate: The treatment is added to the dosage tank and mixed with water. Example: With the 0.5 litres of Vaptreat add sufficient water to make up 50 litres of liquid.The standard flow meter is Adjustable-Rate=0-l00ml/minute.Flow rate calculation: Flowrate = 50 Litres/24 x 60= 35 ml/min setting  i.eThis will last 24 hours.

Note: We can remove  existing  mineral scale deposits  by using  A  5-10%  solution of  RXSOL-51-6001-025 Otherwise to save money and cleaning of HARD DEPOSITS which is formed due to not proper treratment of Evaporator, we have specialized Safe Scale Remover with Indicator ( Product code is RXSOL-22-2210-200 ).

Product Note: 

Improves the quality of distilled water. 

Product Technical Specification: 
CharactersItics   Properties
Appearance Thermal Firmness Clear  yellow liquid 250° C            By keeping heat transfer surfaces free of scale, Ensures that the evaporator works at maximum efficiency.
Density In g/cm3 at 15°C: 1.1

Permits more efficient evaporation.

pH (1 Vol%) 9

Reduces downtime and maintenance costs.

Compatibility   Concentrated, safe liquid, easy and economical dosing.
Metal No known effect

For use in both high pressure and vacuum evaporators

Rubber No known effect The antifoaming properties ensure that distillate quality is high
Packaging

20 / 25 ltr

Improves the quality of distilled water

Product pack size: 
Evaporator Treatment Chemicals for Boiler Water Treatment available in 5, 20, 25, 50, 210 Ltr packing.
Product alias: 
<p> VapourTreatment L, RXSOL Maxi Vap Plus, Ameroyal, Vapour treatment L, Liquivap HC 130, Ameroyal CF, VAPTREAT, VAP TREAT, Eazy Vapcare 25 Ltr, Evaporator Treatment Chemical</p>

RXSOL  Evaporator Treatment is a liquid combination of active polymer and antifoam used to prevent scale deposition in high and low-pressure Evaporators. A liquid mixture of active polymer and antifoam. 

#EvaporatorTreatmentChemicals
#SeawaterEvaporatorTreatmentChemicals
#MarineChemical
#BoilerWaterTreatmentChemicals

Evaporator Treatment is used to stop scale buildup in high and low pressure evaporators system.

VAPT REAT Evaporator Treatment Chemicals supplier in Mumbai, Kandla - Deen Dayal Upadhyay Port, Gandhidham, Chennai - Ennore, Visakhapatnam - Gangavaram, Kolkata - Haldia, Paradip, Fujairah, Dubai, Sharjah, Ajman, AbuDhabi - Middle East - UAE., Nairobi Kenya Africa, CANADA, Ruwi Barka Muscat Oman

Why Evaporator Treatment Chemicals must use?

PREVENTION OF SCALING IN SEA WATER EVAPORATORS.
RXSOL Vapor Treatment Prevents scale formation at temperatures up to 160°C Also Reduces foaming and maintains optimum plant performance.

 

During distilled water production in seawater evaporators, SCALE CONTROL is very important to increase efficiency of distillation as the seawater contains large quantities of salt which is resulting SCALE FORMATION in heat transfer surfaces.  Scale deposits Not only lower plant efficiency by resisting the transfer of heat, But also damaging instruments. Routine use of RXSOL Vapor Treatment prevents Scale formation in the Evaporator SYSTEM.

Whats the Dose Ratio of RXSOL VAPOR TREATMENT Chemicals?

Dilute the RXSOL VAPOR TREATMENT chemicals with water and continuously inject via evaporator inlet or the salt water supply lineand dose into the evaporator system. 30 ml Dose per ton of Seawater is recommended for the prevention of scaling in seawater evaporators. Dose can vary  depends on the capacity and the operating conditions of the evaporator.
Note: for the gradual removal of existing scale deposits, at least twice the normal dose must be used. Remove deposits of more than 2mm, with Descalex Liqui
Articles: 
Remarks: 

RXSOL-51-6001-025 is a concentrated  solution of a POLYELECTROLYTE  polymer and Antifoaming Agents for  use in SEA WATER evaporator  as a controller of scale and foam in side the  evaporators.  It can be used as a scale inhibitor  in the  feed water  to EVAPORATORS producing fresh water .

A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators