Primary tabs

Anti Cracking H2S Corrosion Inhibitor
SKU::RXSOL-81-2065-210
For acid stimulation treatments, the addition of the RXSOL Anti Cracking H2S Corrosion Inhibitor are recommended.
RXSOL H2S-22 corrosion inhibitor is used to control corrosion and inhibit carbon dioxide and hydrogen sulfide. To Prevent H2S Corrosion in distillation Columns overhead system. Hydrogen Sulfide Scavenger -RXSOL-16-2065-210 corrosive and Acidic GAS Remover.
Hydrogen sulfide (H2S) naturally occurs and may already by present information can be the result of sulphate reducing bacteria (SRB) in your process systems. Ones established, it can potentially be carried in hydrocarbon streams, resulting in servere gatharing lines, creating high failure rates in your production.
Through strategic H2S scavenger applications and speciality chemicals, RX Marine International chemicals experts can help reduce H2S levels and lower overall solids in your system, reducing any gas or fluid souring while controlling corrosion.
If you encounter hydrogen sulfide in your system, RX Marine International can perform a fluid compatibility test to determine H2S levels and customize a chemical solution to fit your production needs.
	RXSOL H2S-22 corrosion inhibitor can be applied by continuous injection to maintain active material in the well and production system, or it can be used as an additive in well treatment fluids to provide short-term protection.
	
	Hydrogen Sulfide Scavenger is works as a corrosive Acidic GAS Remover from system as well as from working station. which is not only damaging precious instrument but also creating Worker Health  problem by attacking on respiratory system.
	
	The neutralizing effect of H2S is the result of a simple chemical reaction between the components of an RXSOL-11-5014-210 molecule and an offensive, toxic odour molecule. 
	
	       Hydrogen Sulfide (H2S) + RXSOL-11-5014-210  =  Bi Sulfide salt
	       
	The resultant products in the above equations are safe and stabilized compounds, which are neutral, harmless, and odour free. They dissolve in water and will not be re-released into the atmosphere in normal conditions.
	The RXSOL  Anti Cracking H2S Corrosion Inhibitor is typically mixed in brines or diesel. For acid stimulation treatments, the addition of the RXSOL  Anti Cracking H2S Corrosion Inhibitor and an acid corrosion inhibitor are recommended. 
	
	Benefits:
- Improved safety due to reduced H2S content
 - Meet contract sales limit for H2S content
 - Removal of hydrogen sulfide gas from process systems, therefore reducing corrosion
 - The reaction products can be easily removed from the process systems
 - Maintains asset integrity and reduces the need for new equipment
 
	Hydrogen Sulfide Scavenger Manufacturer, supplier, Exporter. Product Code :  RXSOL-11-5014-210 is very effective  corrosive and Acidic GAS Remover. H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure from atmosphere.
	 
	Typical properties
	Appearance: Dark brown liquid
	Specific gravity: 0.93 +/- 0.03
	Typical temperature range: Up to 250°F (121°C)
	Pour point: <-40°F (-40°C)
	Solubility Slightly dispersible in water; soluble in oil
	HYDROGEN SULFIDE SCAVANGER
	
	MMA Triazine is a cyclic tertiary triamine. It is mainly used as a scavenger for sour gases like H2S and mercaptans in gaseous or liquid hydrocarbon streams
	
	The MMA-triazine reacts with H2S or mercaptan resulting in the formation of dithiazines. Both MMA-triazine and its reaction products are readily biodegradable.
	
	MMA-triazine is available as an aqueous solution with concentration up to 42%.
	
	KEY Feature
	• Can be applied in both aqueous and hydrocarbon streams
	• Effective removal of H2S down to ppm levels
	• Product and its reaction products are readily biodegradable
	TYPICAL PROPERTIES
	Appearance   Clear, colorless liquid
	Autoignition Temperature   190°C
	Boiling Point    100% solution149°C
	Density    42% solution; at 25°C1.02 g/cm3
	Flash Point    Closed Cup88°C
	Freezing Point  42% solution <-50°C
	Freezing Point100% solution <-27°C
	Octanol-water partition coefficient, log Pow   0.76
	Vapor Pressure    @ 20°C2.79-3.4 hPa
	Viscosity  @ 20°C 13 mPa·s
	Viscosity @ 40°C  5.1 mPa·s
Water solubility : Soluble
	Applications • Coiled-tubing intervention in sour well environments • Continuous injection in sour wells to protect tubulars
	
	 
Carbon Dioxide and H2S Corrosion Inhibitor manufacturer and supplier in Mumbai, Kandla, Chennai, Visakhapatnam, Kolkata, Dubai, Fujairah, Sharjah, Abudhabi, Muscat, Sohar, Barka RUWI, Oman, Nairobi Kenya Africa, Canada
	Features and Benefits of RXSOL  Anti Cracking H2S Corrosion Inhibitor : HS-22 corrosion inhibitor Minimize risks in stimulation of sour wells
	
	• Excellent adherence to steel tubulars - Protects tubulars and coiled tubing against stress cracking for the duration of the intervention
	
	• Liquid state - Accurate metering and mixing
	• Low pour point - Can be used in winter operations
	• Compatible with oilfield elastomers - Can be used with a variety of completion and workover components
	• Compatible with common brines, stimulation fluid systems, acid corrosion inhibitors, and other stimulation additives - Facilitates logistics and testing requirements, which reduces associated costs
H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure
Harmful and Colorless toxic gas, Toxic Odor like rotten egg in to the working environment is due to presence of good amount of Hydrogen Sulfide in the system.
	Hydrogen Sulfide is corrosive and Acidic GAS towards metal equipment practically observed that within 5 years can cause millions of dollars in damage to infrastructure.
	
	RX Marine International offers a compleate line of water soluble and oil soluble hydrogen sulfide scavengers that can be applied via continous injection or through batch treatments.
	
	HS Code : 3811900