RXSOL Cooling Pad Cleaner CP is a specialized cleaning formulation developed for the maintenance and cleaning of evaporative cooling pads and associated water distribution components. It helps remove accumulated mineral deposits, scale residues, and stubborn inorganic dirt that can build up during prolonged operation.

The product supports the restoration of clean pad surfaces and helps maintain effective water distribution and airflow through suitable cooling media. Regular cleaning, when performed in accordance with equipment manufacturer recommendations, can help maintain cooling system performance and reduce the accumulation of deposits.

Generic name: Greenhouse Cooling Pad Cleaner
Pack size: This descaler was specifically formulated and developed to rapidly clean mineral scales from passages in water-cooled or heated equipment. Safe Acid Descalex Liquid is available in 25, 50 Ltr packs
Unit: Ltr.
Quantity per unit: 25.00

Application

RXSOL Cooling Pad Cleaner CP is intended for evaluating and cleaning suitable components of evaporative cooling systems, including:

  • Evaporative cooling pads.
  • Industrial air-cooling pad assemblies.
  • Cooling media affected by mineral deposits.
  • Compatible water distribution channels and associated components.
  • Suitable cooling pad surfaces requiring periodic descaling.

Important: Confirm compatibility with the specific cooling pad material and equipment manufacturer's recommendations before use. Do not assume suitability for cellulose, paper-based, impregnated, coated, or polymeric media without compatibility testing.

Other Names

Cooling Pad Cleaner, Cooling Pad Scale Cleaner for Greenhouse

Precautions & Remarks

Fast-acting descaler developed to dissolve mineral scale, rust, and water deposits from boilers, heat exchangers, pipelines, and water-cooled equipment. It enhances plant efficiency, lowers maintenance costs, and minimizes downtime — all without requiring heat during cleaning. This non-combustible, non-flammable formula is safe to handle and can even be used while equipment is in operation. Highly effective against calcium carbonate buildup with minimal manpower. Not recommended for aluminum surfaces.

Which is the best Heat Exchanger Copper Tube Descaling Solution?

Procedure

How to effectively CLEAN Cooling Pad Scale Deposits?

  • The correct cleaning procedure depends on the cooling pad material, deposit type, deposit thickness, and equipment design.
  • Switch off the cooling system and isolate the relevant equipment before cleaning.
  • Inspect the cooling pads for mineral deposits, physical deterioration, and material damage.
  • Consult the cooling pad manufacturer to confirm chemical compatibility and the approved cleaning method.
  • Determine the appropriate dilution, application quantity, and contact time through a controlled preliminary trial.
  • Apply the product using compatible equipment and suitable chemical-resistant protective equipment.
  • Avoid allowing the product to dry on the surface.
  • After the prescribed contact period, thoroughly rinse the cleaned surfaces with clean water using the equipment manufacturer's recommended procedure.
  • Ensure that residual cleaner is removed and that the system is suitable for recommissioning before returning it to service.

Product can be directly sprayed on the cooling pad. NOTE: Always test the product on small area before wide scale application.

Note

 

• Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders

• Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers

. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.

• Buildings - Chillers, Cooling Towers, Pipework

• Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps

• Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables

• Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps

• Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays

• Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators

• Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps

• Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers

• Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps

• Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers

• Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces

• Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers

 

Boilers

Condensers

Filters

Heat Exchangers

Kettles & Tanks

Pipelines

Pots

Reactors

Steam Jackets

Bath Rooms and Showers

Metal Processing and much more!


 

Applications


  Automotive

  Bottling

  Chemicals

  Food

  - Closed Circuit Cooling

  - Dynamometers

  - Extruders

  - Molders

  - Radiators

  - Welders

  - CO2 Generators

  - Heaters

  - Exchangers

  - Rinse Tanks

  - Sterilizers and Washers

  - Dryers

  - Extruders

  - Kettles

  - Mixers

  - Reactors

  - Scrubbers

  - Vacuum Pumps

  - Condensers

  - Ice Machines

  - Kathabars

  - Refrigeration Equipment

  - Steam Tables

  Manufacturing

  Metals

  Mining

  Paper

  - Chillers

  - Compressors

  - Furnaces

  - Quenchers

  - Vacuum Pumps

  - Bearings

  - Conveyors

  - Fans

  - Hearth & Vacuum Furnaces

  - Shelters

  - Sprays

  - Bearings

  - Conveyors

  - Filters

  - Presses

  - Process Lines

  - Radiators

  - Calendar Rolls

  - Mill Rolls

  - Caustic Lines

  - Scrubbers

  - Compressors

  - Liquor Tanks

  - Pulverizers

  - Vacuum Pumps

  Pharmaceutical

  Refinery

  Rubber & Plastics

  Steel

  - Exchangers

  - Loop Systems

  - Kathabars

  - Pumps

  - Reactors

  - Stills

  - Sterilizers

  - Compressors

  - Converters

  - Crackers

  - Exchangers

  - Piping

  - Pumps

  - Banbury Mixers

  - Calendar & Mill Rolls

  - Extruders

  - Injection Molders

  - Molds

  - Temperature Control - Units

  - Throat Coolers

  - Towers and Tubers

  Bearings

  ConCast Units

  Generators

  Hearths

  Spangle Units

  Furnaces

  Textile

  Utilities

  Other Applications

   

  - Air Washers

  - Compressors

  - Condensers

  - Exchangers

  - Extruders and Towers

  - Boilers

  - Turbines

  - Transformers

  - Cooling Towers

  - Air Compressors

  - Hydrogen Coolers

  - Lube Oil Heat Exchangers

  - Ball Mills

  - Demisters

  - Evaporators

  - Locomotives

  - Absorption Units

  - Diesel Generators

  - Induction Furnaces

Keywords

Why using RXSOL Cooling Pad Cleaner CP is better for Cooling Pad Cleaning?
  • Helps remove mineral scale and inorganic deposits.
  • Assists in cleaning heavily soiled cooling pad surfaces.
  • Helps improve water distribution through cleaned media.
  • Supports maintenance of airflow passages in cooling pads.
  • Suitable for controlled maintenance and descaling applications.
  • Viscous consistency facilitates controlled application to suitable surfaces.
  • Helps maintain the cleanliness of cooling system components.

Supply Locations

Cooling Pad Descaling Liquid Manufacturer and supplier in Visakhapatnam Vizag Andhrapradesh, Chennai Ennore Tamilnadu, Kolkata Haldia West Bengal, Gandhidham Surat Gujrat, Mumbai Pune Maharastra, Fujairah UAE Middle East, Dubai, Ajman, Abudhabi, Sharjah, Doha Qatar, Sudan, Kuwait, Muscat Barka Sohar Oman, Yemen, Nairobi Kenya Africa

Dosage

How to effectively CLEAN Cooling Pad Scale Deposits?

  • The correct cleaning procedure depends on the cooling pad material, deposit type, deposit thickness, and equipment design.
  • Switch off the cooling system and isolate the relevant equipment before cleaning.
  • Inspect the cooling pads for mineral deposits, physical deterioration, and material damage.
  • Consult the cooling pad manufacturer to confirm chemical compatibility and the approved cleaning method.
  • Determine the appropriate dilution, application quantity, and contact time through a controlled preliminary trial.
  • Apply the product using compatible equipment and suitable chemical-resistant protective equipment.
  • Avoid allowing the product to dry on the surface.
  • After the prescribed contact period, thoroughly rinse the cleaned surfaces with clean water using the equipment manufacturer's recommended procedure.
  • Ensure that residual cleaner is removed and that the system is suitable for recommissioning before returning it to service.

Product can be directly sprayed on the cooling pad. NOTE: Always test the product on small area before wide scale application.